Amamitha Okugeleza Kwe-Ultrasonic

Iminyaka engaphezu kwengu-20 yesipiliyoni sokukhiqiza

uma isilinganiso sesikhathi esiboniswa ku-M91 sidlula ububanzi obungu-100±3%, (Leli nje inani lokubhekisela), umsebenzisi kufanele ahlole:

1) Uma amapharamitha epayipi efakwe kahle.
2) Uma isikhala sangempela sokubeka sihambisana kahle nenani le-M25.
3) Uma ama-transducer efakwe kahle ngezindlela ezifanele.
4) Uma ubude bepayipi eliqondile kwanele.
5) Uma umsebenzi wokulungiselela usuwenziwe njengoba kuchaziwe ngenhla.
6) Uma ipayipi liphambukile noma uma kukhona ukungcola okuningi ngaphakathi.
Qaphela: Ukuqinisekisa ukuthi u-1-6 awunankinga, bese ulungisa ibanga lama-transducers libe yi-qiniseka ukuthi i-TOM/TOS=97-103% kumenyu91. Uma usondela ku-100%, kungcono.
I-Whatsapp:+86 189 1792 0598

Isikhathi sokuthunyelwe: Mashi-07-2022

Thumela umlayezo wakho kithi: